|   Gated Triggering with Single-Channel Updating  This configuration allows an external logic signal to 
temporarily suspend and reactivate updating. When active,
analog output values are updated according to the internal
clock. 
Notes: 
	Clocking can start when trigger is held active high at least tTrigMinClocking activity begins tTCsetupafter triggering goes activeData must be fetched from buffer and stable at converter before clockingUpdates are latched into the converter at clocked intervals TIMEAnalog output values stabilize after settling transient Clocking activity is suspended when the trigger level goes inactive low Lower the trigger level within tTrigMaxto exclude the next clockUpdating can resume after the trigger level again goes active high  |